# X-90T Experimental V1 - 3,000 SHP Turbine Changelog Based on the uploaded stock Black Square turbine `engines(2).cfg` and `BonanzaProfessional_Turbine_INT.xml`. No stock package files are changed by this installer. | Item | Stock | V1 | Rationale | |---|---|---|---| | Rated shaft power | 500 SHP | 3,000 SHP | Display target only; not direct physical power parameter | | Engine maximum torque (physical model) | 1,200 ft-lb | 6,200 ft-lb | Along with altitude multipliers produces enough shaft torque for ~3,000 SHP | | Automatic torque cap (physical model) | 5,000 ft-lb | 7,500 ft-lb | ~3,141 SHP cap at 2,200 RPM; necessary for 3,000 SHP target | | Black Square indicated torque | Actual ft-lb | 1/3 actual ft-lb | Keeps doubled cockpit protection threshold usable; printed dial markings no longer accurate | | Indicated torque damage onset | 1,250 | 2,500 normalized units | Exactly double the prior Black Square threshold; equivalent 7,500 actual ft-lb | | Sustained ITT damage threshold | 715 C | 850 C | Hypothetical high-temp turbine limit; damage logic retained | | Severe ITT damage threshold | 1,090 C | 1,250 C | Severe exceedance still accumulates damage | | Turbine fuel-control full throttle commanded flow | 370 lb/hr | 1,320 lb/hr | Allows ~3,000 SHP class fuel feed | | Engine high-fuel-flow and max fuel-flow parameters | 350 lb/hr | 1,350 lb/hr | Keeps engine-side model aligned with custom controller | | Power-specific fuel consumption | 0.365 | 0.42 lb/SHP/hr | Roughly 1,260 lb/hr at 3,000 SHP, before sim-specific scaling | | Oil cooling constant | 0.20 | 0.27 | Modest additional simulated oil cooling | | Governor / gearbox / blade count | Stock | Unchanged | No unproven high RPM change; propeller may be bottleneck | | Flight model / fuel tanks / airframe limits | Stock | Unchanged | Explicitly out of scope for V1 | ## Engineering limitations - The user's requested doubling of torque limits is implemented on the Black Square **indicated torque scale** (1250 to 2500). In **real simulated shaft torque**, doubling the original 1200 ft-lb is insufficient for 3000 SHP at ~2200 prop RPM. A 7500 ft-lb ceiling is therefore required. - The simulated ITT limit is **not** evidence that a real PT6-family hot section could survive 850 C continuously. - The unmodified 4-blade propeller, governor and gearbox may not absorb the new torque; RPM overspeed is possible. - Changing rated_shaft_hp alone does not increase actual simulated power. - At full power, a 124-gallon stock fuel load might last well under an hour depending on fuel demand. - The system may model only partial torque despite increased tables, and visual gauge scales may mislead. Verify with external data readouts.